CC-Link | Peripheral devices | Parts built into devices・ASIC
MITSUBISHI ELECTRIC CORPORATION
Q50BD-CCV2 type interface board
 |
 |
Features
- Master stations, stand-by master stations, local stations, and intelligent device stations can be easily developed with the board. Functions necessary for the master stations, stand-by master stations, local stations, and intelligent device stations can be materialized with the interface board mounted on customer boards.
- Compatibility with CC-Link Ver.2
The compatibility with CC-Link Ver.2 enables the cyclic point to be increased to 8192 for RX/RY and 2048 words for RWr/RWw per network at a maximum. It is also compatible with the old specification (ver.1).
- Space saving
The board is in the small size of 70 mm × 80 mm.
- It can readily communicate with circuits on user boards via a general purpose interface bus. As the interface between the user boards and interface board is carried out with general memory control signals (address, data, and read/write buses, etc.), communication with the user boards is easy.
|
Specifications
| Station type |
Master station, local station,
intelligent device station |
| Number of stations occupied |
|
| CC-Link version |
Ver.2 |
| External dimensions |
70.0×80.0 mm |
| Weight |
0.03 kg |

|