MITSUBISHI ELECTRIC CORPORATION
FREQROL-A700 Series General-purpose inverter
Highest level in your hand
High-performance/high-function inverter
 
Features
Performance Enhancement
  • High accuracy/fast response speed operation by the vector control can be performed with a general-purpose motor without encoder.
    Also permits torque limits during torque control and speed control.
  • Vector control operation can be performed using a motor with encoder.
    Torque control/position control as well as zero speed control, servo lock can be realized with the inverter.
Improved Reliability & Maintainability
  • Lengthens the life of cooling fans and capacitors.
  • A self-diagnosis function outputs parts life alarm and monitors degrees of deterioration, permitting corrective measures to be taken before problems occur.
  • A removable terminal block and cooling fan cassette simplify replacement procedures.
Environment Friendly
  • A newly developed, built-in noise filter (EMC filter) reduces noise emissions from the inverter.
Easy to Use
  • When CC-Link is running, operation can be controlled by X, Y commands from a PLC, making program creation easy.
 
Specifications
Item Contents
Power supply Three-phase 200V Three-phase 400V
Capacity range 0.4kW to 90kW 0.4kW to 500kW
Control method Soft-PWM control/high carrier frequency PWM control (selectable from among V/F control, advanced magnetic flux vector control and real sensorless vector control) / vector control (when used with option FR-A7AP)
Starting torque 200% 0.3Hz (0.4K to 3.7K), 150% 0.3Hz (5.5K or more) Under real sensorless vector control
Output frequency range 0.2 to 400Hz
Overload current rating 150% 60s, 200% 3s
Acceleration/deceleration time setting 0 to 3600S (Up to 3 types of individual acceleration/deceleration settings possible)
Protective function Overcurrent shutoff, regenerative overvoltage shutoff, overload shutoff, input/output phase failure, undervoltage, output side earth (ground) fault overcurrent, stall prevention, instantaneous power failure, etc.
Main control function PID control, automatic restart after instantaneous power failure, power-failure deceleration stop, original operation continuation at instantaneous power failure, regeneration avoidance, pulse train input/output, automatic tuning, etc.
CC-Link interface (CC-Link communication is possible simply by installing FR-A7NC) Number of units connected Max. 42 units (different types can be used together)
Station type Remote device station
Occupied station Ver.1: 1 station occupied, Ver.2: 1 station occupied (×2, ×4, and ×8 selection possible)
 
Standard price
Please contact.

Release
Now on sale