MITSUBISHI ELECTRIC CORPORATION
FREQROL-A700 Series General-purpose inverter |
|
 |
 |
 |
Highest level in your hand
High-performance/high-function inverter |
| |
| Features |
 |
| ● |
Performance Enhancement
- High accuracy/fast response speed operation by the vector control can be performed with a general-purpose motor without encoder.
Also permits torque limits during torque control and speed control.
- Vector control operation can be performed using a motor with encoder.
Torque control/position control as well as zero speed control, servo lock can be realized with the inverter.
|
| ● |
Improved Reliability & Maintainability
- Lengthens the life of cooling fans and capacitors.
- A self-diagnosis function outputs parts life alarm and monitors degrees of deterioration, permitting corrective measures to be taken before problems occur.
- A removable terminal block and cooling fan cassette simplify replacement procedures.
|
| ● |
Environment Friendly
- A newly developed, built-in noise filter (EMC filter) reduces noise emissions from the inverter.
|
| ● |
Easy to Use
- When CC-Link is running, operation can be controlled by X, Y commands from a PLC, making program creation easy.
|
|
|
|
| |
| Specifications |
| Item |
Contents |
| Power supply |
Three-phase 200V |
Three-phase 400V |
| Capacity range |
0.4kW to 90kW |
0.4kW to 500kW |
| Control method |
Soft-PWM control/high carrier frequency PWM control (selectable from among V/F control, advanced magnetic flux vector control and real sensorless vector control) / vector control (when used with option FR-A7AP) |
| Starting torque |
200% 0.3Hz (0.4K to 3.7K), 150% 0.3Hz (5.5K or more) Under real sensorless vector control |
| Output frequency range |
0.2 to 400Hz |
| Overload current rating |
150% 60s, 200% 3s |
| Acceleration/deceleration time setting |
0 to 3600S (Up to 3 types of individual acceleration/deceleration settings possible) |
| Protective function |
Overcurrent shutoff, regenerative overvoltage shutoff, overload shutoff, input/output phase failure, undervoltage, output side earth (ground) fault overcurrent, stall prevention, instantaneous power failure, etc. |
| Main control function |
PID control, automatic restart after instantaneous power failure, power-failure deceleration stop, original operation continuation at instantaneous power failure, regeneration avoidance, pulse train input/output, automatic tuning, etc. |
| CC-Link interface (CC-Link communication is possible simply by installing FR-A7NC) |
Number of units connected |
Max. 42 units (different types can be used together) |
| Station type |
Remote device station |
| Occupied station |
Ver.1: 1 station occupied, Ver.2: 1 station occupied (×2, ×4, and ×8 selection possible) |
|
| |
Standard price Please contact.
Release
Now on sale
|
| |
| |
|